Send Message

OEM Current Limiting Reactors Hollow Neutral Grounding Reactor For Shunt Reactor

Basic Information
Place of Origin: XI'AN CHINA
Brand Name: HERONG ELECTRIC
Certification: ISO9001
Model Number: ZJ K K-□-□
Minimum Order Quantity: 1PC
Price: Negotiable
Packaging Details: Export wooden packing
Delivery Time: 30-45 DAYS
Payment Terms: L/C, T/T, D/P, T/T, Western Union, MoneyGram
Supply Ability: 1000SET/YEAR
Installation Site: Outdoors Or Indoors, When Used Indoors, There Must Be Good Ventilation Conditions Ambient Temperature: -40℃~+45℃
Altitude: ≤1000m Relative Humidity: (Indoor) The Monthly Average Relative Humidity Does Not Exceed 90%, And The Daily Average Does Not Exceed 95%
Seismic Fracture: The Horizontal Acceleration Is 0.3g, The Vertical Acceleration Is 0.15g Maximum Wind Speed: Maximum Wind Speed Is 35m/s
High Light:

OEM Current Limiting Reactors

,

Current Limiting Reactors Hollow Neutral Grounding

,

OEM Neutral Grounding Reactor For Shunt Reactor

Dry-Type Hollow Neutral Grounding Reactor,Current Limiting Reactors

 

1. Overview of Dry-Type Hollow Neutral Grounding Reactor,Current Limiting Reactors

 

The dry-type hollow neutral grounding reactor is a multi-layer parallel cylindrical structure, that is, a single-layer coil is wound on the winding die with a thinner insulated aluminum wire, and the multiple single-layer coils are made of long glass impregnated with epoxy resin The fiber tows are wrapped to form an envelope, and then a number of envelopes are coaxially stacked on this envelope in turn, and the envelopes are separated and supported by resin glass fiber drawing strips to form an axial heat dissipation air passage. After the preparation is completed, it will solidify to form a solid whole.


 2. Purpose of Dry-Type Hollow Neutral Grounding Reactor,Current Limiting Reactors

The reactor is mainly connected between the three-phase neutral point of the high reactance or the transformer and the ground to limit the line-to-ground current to an appropriate value when the system is grounded. The neutral point of the 500kV main transformer uses 66kV dry-type hollow neutral Point reactor, the neutral point of the 750kV main transformer uses a 110kV dry-type hollow neutral point reactor.

3. Main features of Dry-Type Hollow Neutral Grounding Reactor,Current Limiting Reactors

OEM Current Limiting Reactors Hollow Neutral Grounding Reactor For Shunt Reactor 0

4.Executive standard of Dry-Type Hollow Neutral Grounding Reactor,Current Limiting Reactors

GB/T 1094.6-2011

5. Conditions of use


(1) Altitude: no more than 1000 meters.
(2) Ambient temperature: -40~45℃.
(3) Relative humidity: not more than 90%.
(4) Wind speed: ≤ 35m/s.
(5) Earthquake intensity: not more than 8.
(6) Installation location: indoor or outdoor.

Contact Details
Amanda

Phone Number : +86-18740359806

WhatsApp : +8618202998636